4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Control Bus
Original bus (16 bit, 8 MHz,10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slot)
Switching
Non Blocking Distributed Time Switch
Power Input
PSU-M
(KX-TDA0104)
(KX-TDA0104)
100 V AC to 130 V AC/200 V AC to 240 V AC, 2.5 A/1.4 A, 50 Hz/60 Hz
PSU-L
(KX-TDA0103)
(KX-TDA0103)
100 V AC to 130 V AC/200 V AC to 240 V AC,5.1 A/2.55 A, 50 Hz/60 Hz
External Battery
+36 V DC (+12 V DC x 3, battery capacity of 28 Ah or below recommended for 1 external
battery)
battery)
Maximum Power Failure Tolerance
300 ms (without using backup battery)
Memory Backup Duration
7 years
Dialling
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Tone (DTMF) Dialling
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
Ω maximum
Operating
Environment
Environment
Temperature
0 °C to 40 °C
Humidity
10%to 90% (non condensing)
Conference Call Trunk
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -6 dB to +3 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
PT-interface CS
1-pair wire (D1, D2)
DSS Consoles and Add-on Key Module
1-pair wire (D1, D2)
Dimension
KX-TDA200
430 mm (W) x 415 mm (H) x 270 mm (D)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
(17 1/5 in x 16 3/5 in x 10 4/5 in)
Weight (when fully mounted) KX-TDA200
Under 16 kg (35.2 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
•
•
•
• PT: KX-T7600 series: 90 Ω; all other DPTs/APTs: 40 Ω
•
•
•
• SLT: 600 Ω including set
•
•
•
• Doorphone: 20 Ω
•
•
•
• CS: 130 Ω; PT-interface CS: 65 Ω
Minimum Leakage Resistance
15000
Ω maximum
Maximum Number of Extension
Instruments per Line
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of two DPTs and an SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of two DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
Ω maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. The main unit (Hybrid IP-PBX) detects input from the sensor when the signal
is under 100
the EIO4 card. The main unit (Hybrid IP-PBX) detects input from the sensor when the signal
is under 100
Ω.
Paging Terminal Impedance
600
Ω
MOH (Music on Hold) Terminal Impedance
10000
Ω
6
KX-TDA200UA