KX-TDA0103X/KX-TDA0103XJ/KX-TDA0104X/KX-TDA0104XJ
3 Specifications
3.1.
General Description
KX-TDA0103X/KX-TDA0103XJ
KX-TDA0104X/KX-TDA0104XJ
3.2.
System Capacity
3.2.1.
Power Supply Unit Selection
Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the amount of "load figures" 
from the type and number of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different amount of load figures.
Input
voltage
AC100-130V/AC200-240V
current
5.1A/2.55A
frequency
50/60Hz 
Output
ch.
+15V
+15VPT
+30V
+41V
voltage
15V
15V
30V
41V
current (rated)
3.20A
15.4A
0.73A
4.50A
total output power
279 W
Input
voltage
AC100-130V/AC200-240V
current
2.5A/1.4A
frequency
50/60Hz 
Output
ch.
+15V
+15VPT
+30V
+41V
voltage
15V
15V
30V
41V
current (rated)
3.20A
3.84A
0.73A
2.25A
total output power
140.4 W
Equipment Type
Load Figure
PT
DPT (T76xx series and T7560, T7565) 1
Other DPT/APT/DSS Console
4
Extension Card *1
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS
4
ISDN Extension
2
Voice Mail
1
PSU Type
Maximum Load Figures
Available
PSU-M (KX-TDA0104)
128
Available for the KX-TDA100 and KX-TDA200 and KX-TDA600
PSU-L (KX-TDA0103)
512
Available for the KX-TDA200 and KX-TDA600