KX-NTV160NE (serv.man2) - Panasonic PBX Service Manual (repair manual). Page 13

Read Panasonic KX-NTV160NE (serv.man2) Service Manual online

13
KX-NTV160 Series  
8.2.
Measure the circuit after disassembly
Before connecting to power source, measuring if VCC( VDD) to GND is short with multimeter.
Step4
A. Remove 4 screw of main board (red circle).
B. Remove 3 screws of sensor board (green circle).
Step5
A. Ttake out sensor board and main board.
Step1
A. Turn the multimeter to resistance setting (Ω) 
     (with beep function).
B. Measure main board PCBA (TP14_GND) with COM probe of 
multimeter.
C. Measure main board PCBA (TP20_5V9V) with Ω probe of 
multimeter, the circuit is short if there's beep sound; if not, the 
circuit is normal.
Step2
A. Turn the multimeter to resistance setting (Ω) 
     (with beep function).
B. Measure main board PCBA (TP14_GND) with COM probe of 
multimeter.
C. Measure main board PCBA (D24_Pin1) with Ω probe of 
multimeter, the circuit is short if there's beep sound; if not, the 
circuit is normal.
Page of 37