KX-NS5290CE - Panasonic PBX Service Manual (repair manual). Page 8

Read Panasonic KX-NS5290CE Service Manual online

8
KX-NS5290CE
4.3.
Outline of Reset System
A reset to devices(IC501, IC502 and IC505) in this card is controlled by reset signals from PLD(IC506). 
Shows the reset schematic diagram.
4.4.
Power Supply
This card is supplied +3.3V power through the SMT connector (CN501) via Base card.
4.5.
Local Highway Interface
The PCM data of arbitrary streams (128 timeslot / 1 stream) on the bus can switch to the arbitrary local highway (64timeslot) by the
local TSW.
TS No.
PCM data
TS No.
PCM data
96
PRI30#1/PRI23_FSDL/LCOT#7
112
PRI30#16/PRI23#16
97
PRI30#2/PRI23#1/LCOT#8
113
PRI30#17/PRI23#17
98
PRI30#3/PRI23#2/LCOT#9
114
PRI30#18/PRI23#18
99
PRI30#4/PRI23#3/LCOT#10
115
PRI30#19/PRI23#19
100
PRI30#5/PRI23#4/LCOT#11
116
PRI30#20/PRI23#20
101
PRI30#6/PRI23#5/LCOT#12
117
PRI30#21/PRI23#21
102
PRI30#7/PRI23#6/BRI#1_B1
118
PRI30#22/PRI23#22
103
PRI30#8/PRI23#7/BRI#1_B2
119
PRI30#23/PRI23#23
104
PRI30#9/PRI23#8/BRI#2_B1
120
PRI30#24/PRI23#24(DCH)
105
PRI30#10/PRI23#9/BRI#2_B2
121
PRI30#25
106
PRI30#11/PRI23#10/BRI#3_B1
122
PRI30#26
107
PRI30#12/PRI23#11/BRI#3_B2
123
PRI30#27
108
PRI30#13/PRI23#12/BRI#4_B1
124
PRI30#28
109
PRI30#14/PRI23#13/BRI#4_B2
125
PRI30#29
110
PRI30#15/PRI23#14/DoorPhone#3
126
PRI30#30
111
PRI23#15//DoorPhone#4
127
reserve
FLAMER (IC501)
TI DSP (IC502)
DSPG (IC505)
PLD (IC506)
RESET command by sofware
nRESET_FALC56
nRESET_DSPG
nRESET_TI-DSP
Page of 31