KX-HTS32\KX-HTS824 Series
3.2.
Characteristics
Terminal Equipment Loop Limit
SLT: 600 Ω including set
Doorphone: 20 Ω
Minimum Leakage Resistance
15 000 Ω minimum
Maximum Number of Extension
Instruments per Line
1 for SLT
Ring Voltage
65 Vrms at 20 Hz/25 Hz depending on the Ringing Load
For Malaysia, 75 Vrms
Trunk Loop Limit
1600 Ω maximum
Hookswitch Flash/Recall Timing
Range
24 ms to 2032 ms