100
10.1.4.3. Adjusting the Horizontal Scanning Position between CIS2 and CIS3
(1) Enter the Service Mode. (See 9.1.)
(2) Press the "Menu Key" or the "2-Screen Copy Key" until "Hh" (Item: Adjusting the Horizontal Scanning Position (between CIS2
and CIS3)) appears on the Display Window.
(3) By pressing the "Multi-Copy/Stop Key", the current alignment value will be displayed.
Then, press the "Menu Key" or the "2-Screen Copy Key" to change the value.
(4) Press the "Multi-Copy/Stop Key" to set the new value.
(5) Perform the "Adjustment Pattern Output". (See 10.1.2.)
Then, check that the CIS alignment is proper.
Then, check that the CIS alignment is proper.
10.1.5. Shading Waveform Backup
After finishing the Image Sensor's adjustment, the following operation is required to store the shading waveform of the Image Sensor
in the back-up memory.
in the back-up memory.
(1) Enter the Service Mode. (See 9.1.)
(2) Press the "Menu Key" or the "2-Screen Copy Key" until "HL" (Item: Initializing Shading Data) appears on the Display Window.
(3) Press the "Multi-Copy/Stop Key" to perform initializing.
(4) When "HL" (Item: Initializing Shading Data) appears on the Display Window again, restart the Panaboard.
(5) Check that Shading Error "U32"/"U33" is not displayed.