UB-2315C, UB-2815C - Panasonic Other Service Manuals Service Manual Supplement (repair manual). Page 2

Read Panasonic UB-2315C / UB-2815C Service Manual Supplement online

2
1 Description
The Scanner unit, its related parts (control board, motor driver board, etc.) and firmware have been changed for production reason. 
• The scanner assembly of the scanner unit has been changed from “LED type” to “Light Guide type”, and the serial number suffix
was changed from “B” to “C” with this change. This modification has been performed on all units as of serial suffix “C and later”.
• By this modification, the control board, its related parts (regarding the detail information, refer to section 3 “Exploded View and
Replacement Parts List”.) and firmware (refer to the section 2 “Change of the Service Mode.) have been changed, and the new
part number (PPB875PBU11) for the control board was created. The new control board (PPB875PBU11) can be used on the
LED type or Light Guide type scanner assembly, however, make sure that the scanner type setting of service mode is correctly
set to the scanner used.
2 Change of the Service Mode
By the firmware change as shown below, section 7 “Service Mode” of the service manual is changed like a subsequent section
(section 2.2 “Change of the section 7 “Service Mode”.).
2.1.
Changing Contents of the Firmware
Item No.
Description
1
Version Number is changed: 1.01 
→ 2.10
2
Color image processing for Light Guide is supported.
3
Light source selection of LED Array or Light Guide is added in the Initial Setting Mode and the Service Mode.
Additional Item
Content
Scanner: LED   Lt-Gd
For setting the scanner unit type. Set according to the scanner unit.
4.
Following functions are added in the Service Mode.
Additional Item
Content
a
USB-Flash: On   Off
On: USB flash memory enable
Off: USB flash memory disable
b
SD-Card: On   Off
On: SD memory card enable
Off: SD memory card disable
c
Init-ShadBkup>>>
The backup shading wave form is initialized.
Execute this mode after exchanging the scanner unit.
d
Img-PatternSide: 1  2
For setting the image quality mode on both sides of the scanner unit.
This value is fixed to 2.
e
Img-PatternAll: 1  2  3
For setting the image quality mode of the scanner unit.
This value is fixed to 1.
5.
Unit of the slice level is changed from “Setting Value”/240 to percentage.
a
Slice-Std:   168 
→ 70%
*Default: 168/240 = 70%
b
Slice-Dark:   192 
→ 80%
*Default: 192/240 = 80%