3) Touch and Feel 
a) Feel the compressor when running ,its temperature should be generally less than 90°C in the 
normal state (it may exceed 90°C in case of running for a longer period of time ). 
b) After the compressor has operated normally for 5~10 minutes , touch and feel the condenser ,the 
temperature of its upper part should be higher than that of its lower part (or its right part is hotter 
than its left part ,depending on the type of condenser coil ),this indicates that the refrigerant is 
circulating . If the condenser is not hot, this means the leakage of refrigerant .In case the condenser 
radiates heat for only several minutes and then cools down ,this means that the filter and capillary 
have been clogged .As for the forced air cooling condenser ,hot air will be blown out of it ;this means 
that the system is out of order . 
 
c) Feel the filter's temperature .During the normal operation of refrigerating system ,the temperature 
on the filter's surface should be a little higher than the ambient temperature ;if you touch it with your 
hand ,you will have a sense of slight heat .In case dew condensation appears due to the fact that its 
temperature is obviously lower than the ambient temperature ,this means that most meshes of its 
screen has been clogged ,resulting in an obstructed flowing of refrigerant ,thus causing a drop in 
temperature due to throttling . 
 
d) Feel the temperature of exhaust gas from the refrigerating system .the exhaust gas should be 
very hot and this is the normal working state .For those refrigerator with enclosed type of 
compressor refrigerating system, no frost or dew drop will from on the gas suction tube, 
otherwise ,there is something wrong in the system (Frosting and dew condensation may appear for 
a very short time period when just starting the machine ,this is a normal phenomenon ). Because a 
refrigerator is a combination of several components ,they are related and have influence on each 
other In case an abnormal phenomenon has been found through the above-mentioned 
checkups ,you need not to make a hasty conclusion based on only one abnormal phenomenon .It is 
advisable to find out two or more abnormal phenomenon ,or conduct troubleshooting 
comprehensively with the aid of instruments or other ways ,because several kinds of troubles may 
share a common abnormal phenomenon ,and two or more abnormal phenomena may occur 
simultaneously due to a certain trouble .With this method ,you can reject some suspicious troubles 
and finally make a correct judgment . 
 
 
 
 
 
 
 
 
 
 
 
 
 