112
F43 (Background Plate 
drive error) 
Platen Motor does not work.
Check both gears. 
1. Check the following connection and 
soldering condition.
a. Platen Motor to CN2022 (DRIVE Board)
b. CN2008 (DRIVE Board) to CN15 
    (CONTROL Board)
c. CN5110 (PLATEN HOME SENSOR
 
   
Board)  to CN21 (CONTROL Board )
2. Check the soldering condition of IC2023, 
IC2011 (DRIVE Board) and its surrounding 
circuits.
3. Check the soldering condition of IC5110 
(PLATEN HOME SENSOR Board) and its 
surrounding circuits.
4. Replace faulty parts or Boards.
F45 (Stacker error) 
35
x
00
00 1. Stacker Motor does not work 
properly.
1. Check the motor mechanism condition by 
carrying out “Stacker motor” test in Sec. 
10.3.7.
2. Check the following cable connection and 
cable.
  Stacker Motor to CN2019 (DRIVE Board).
3. Try to exchange two of FFC cable between 
the DRIVE Board and the CONTROL Board. 
(If repaired, FFC cable breakage).
4. Replace Stacker Motor.
2. Stacker Motor control circuit 
does not work properly.
1. Check the following connections and 
soldering condition.
CN15 (CONTROL Board) to CN2008 
(DRIVE Board)
2. Check the soldering condition of IC2021 
(DRIVE Board) and its surrounding circuits.
3.  Check the following signals of DRIVE Board.
a. IC2021-14th pin (CLK): See Fig. 1.
b. IC2021-15th pin (VREF): 2.5 V or less.
c. IC2021-2nd pin (ENABLE): 3.3 V
    (During driving the motor)
3. Stacker Home Detector does not 
work correctly
1. Check the following connection and 
soldering condition on each connector.
a. CN5170 (STACKER HOME SENSOR 
    Board) to CN3003 (UPPER RELAY Board)
b. CN3004 (UPPER RELAY Board) to CN19 
    (CONTROL Board)
2. Check the soldering condition of IC5170 
(STACKER HOME SENSOR Board) and its 
surrounding parts.
4. Stacker Limit Detector does not 
work correctly.
1. Check the following connection and 
soldering condition on each connector.
a. CN5180 (STACKER UPPER LIMIT 
    SENSOR Board) to CN3003 (UPPER 
    RELAY Board)
b. CN3004 (UPPER RELAY Board) to CN19 
    (CONTROL Board)
2. Check the soldering condition of IC5180 
(STACKER UPPER LIMIT SENSOR Board) 
and its surrounding parts.
F60 (Front-side gain
adjustment error)
50
00
00
00 1. Scanning Glass (F) is dirty.
Clean the glass surface. (See Sec. 9)
Error Code
ST1 ST2 ST3 ST4
Possible Cause
Recommended action
Remarks
Page of 127