Read Panasonic KV-S4065CL / KV-S4065CW / KV-S4065CWCN / KV-S4085CL / KV-S4085CW / KV-S4085CWCN Service Manual online
115
Note:
*8
For LED and indicators’ position shown in the above figure, see Sec. 3.
7.
*9
CIS LED
Lamp Test
1 While pushing the “START/STOP Key” on the Control
Panel, turn on the scanner.
—
—
*9: Every time you
push the
“START/STOP”
Key, the lamp
status will change
periodically, as
follows.
push the
“START/STOP”
Key, the lamp
status will change
periodically, as
follows.
Lamp (F) ON
Lamp (B) OFF
Lamp (B) OFF
↓
Lamp (F) OFF
Lamp (B) ON
Lamp (B) ON
↓
Lamp (F) ON
Lamp (B) ON
Lamp (B) ON
↓
Lamp (F) OFF
Lamp (B) OFF
Lamp (B) OFF
↓
Lamp (F) ON
Lamp (B) OFF
Lamp (B) OFF
↓
2 Release the key after LED (Back) status changes to
blinking.
OFF
→
Blinking
3 Push the “START/STOP Key” once to enter the test
selection mode.
Blinking
→
Count
4 Push the “START/STOP Key” once at the timing when
LED (Back) status is 7 (h)
*7
.
5 Push the “START/STOP Key” once to turn on the CIS
LED Lamp (F).
6 Push the “START/STOP Key” once to turn off the CIS
LED Lamp (F) and to turn on the CIS LED Lamp (B).
7 Push the “START/STOP Key” once to turn on the CIS
LED Lamp (F) and CIS LED Lamp (B).
8 Push the “START/STOP Key” once to turn off the CIS
LED Lamp (F) and CIS LED Lamp (B).
9 Turn off the scanner to finish this test.
—
—
Click on the first or last page to see other KV-S4065CL / KV-S4065CW / KV-S4065CWCN / KV-S4085CL / KV-S4085CW / KV-S4085CWCN service manuals if exist.