KV-S1058Y, KV-S1028Y, KV-S1057C-M2, KV-S1057C-J2, KV-S1027C-M2, KV-S1027C-J2 (serv.man2) - Panasonic Other Service Manuals Service Manual Supplement (repair manual). Page 5

Read Panasonic KV-S1058Y / KV-S1028Y / KV-S1057C-M2 / KV-S1057C-J2 / KV-S1027C-M2 / KV-S1027C-J2 (serv.man2) Service Manual Supplement online

5
KV-S1058Y/KV-S1028Y/KV-S1057C-M2/J2/KV-S1027C-M2/J2
9. FAN dose not rotate.
1. Try to rotate the FAN, manually.
2. Check the power supply to the FAN.
3. Replace the FAN.
Scanner does not 
recognize USB 
connection.
1. USB cable is not connected normally.
1. Check the device (USB) condition of PC with Device 
Manager.
2. Re-attach the USB cable, and then restart the scanner 
and PC.
3. Replace the USB cable.
2. USB interface circuit does not work.
1. Check the soldering condition of the following parts and of 
their surrounding circuits on the CONTROL Board, and 
then repair it.
(1) JK3 (USB IF connector)
(2) LF4 (Common mode filter)
(3) LF6 (Common mode filter)
(4) IC9 (PF4)
2. Replace the CONTROL Board.
START/STOP Button, 
Skip Button, or Cursor 
Button don’t work 
properly.
1. Mechanical problem with ON/OFF 
    switch.
1. Perform the "Key / Sensor" test in Sec. 
10.3.8.
 to check 
following button's ON/OFF status.
(1) [Start/Stop] SW4100 on PANEL SWITCH Board
(2) [Skip] SW4101 on PANEL SWITCH Board
(3) [Up] SW4102 on PANEL SWITCH Board
(4) [Down] SW4103 on PANEL SWITCH Board
(5) [Left] SW4104 on PANEL SWITCH Board
(6) [Right] SW4105 on PANEL SWITCH Board
(7) [Set] SW4106 on PANEL SWITCH Board
2. Check the button’s ON/OFF mechanical condition.
3. Replace faulty parts.
2. ON/OFF monitor circuit does not 
function.
1. Check the soldering condition of the following parts and of 
their surrounding circuits on the PANEL SWITCH Board.
(1) SW4100, R4101
(2) SW4101, R4102
(3) SW4102, R4100
(4) SW4103, R4106
(5) SW4104, R4105
(6) SW4105, R4103
(7) SW4106, R4104
2. Check the following connection.
(1) Between CN4000 (LCD PANEL Board) and CN10 
(CONTROL Board)
(2) FFC Cable
(3) Between CN4002 (LCD PANEL Board) and CN4100 
(PANEL SWITCH Board)
3. Check the soldering condition of the following parts and 
their surrounding circuits on the CONTROL Board.
(1) CN10
4. Check the following signals on the LCD PANEL Board.
IC4000
5. Replace faulty parts or boards.
Scanning position is 
shifted.
1. After replacing or re-assembling the 
CIS assembly and/or mechanical parts 
related to conveying documents, 
re-adjustment of scanning position has 
not been done.
1. Perform the "All Position" and/or "Individual Position" 
in Sec.
10.3.9.
 so that the scanning position can be 
adjusted properly.
2. The CIS assembly is not installed 
properly. 
1. Re-assemble the CIS Assembly. (See Sec 
8.3.5.
 & 
8.4.2.
Symptom
Possible Cause
Recommended action
Page of 14
Display

Click on the first or last page to see other KV-S1058Y / KV-S1028Y / KV-S1057C-M2 / KV-S1057C-J2 / KV-S1027C-M2 / KV-S1027C-J2 (serv.man2) service manuals if exist.