Read Panasonic KV-S1045C Service Manual online
24
7.3.2.
Double-feed Prevention Roller
(1) Remove the Feed Tray. (See 7.2.1.)
(2) Push the Door Open Button to open the ADF Door.
(See 7.2.1.)
(3) Open the Double-feed Prevention Roller Cover in the
direction of the arrow, holding the Double-feed Prevention
Roller so as not to drop it.
direction of the arrow, holding the Double-feed Prevention
Roller so as not to drop it.
(4) Remove the Double-feed Prevention Roller.
(5) Take a new Double-feed Prevention Roller out of the
Roller Exchange Kit (KV-SS035).
Roller Exchange Kit (KV-SS035).
(6) Install the new Double-feed Prevention Roller into the
metal holder with the longer groove on the right side
(as seen form the back), and close the Double-feed
Prevention Roller Cover.
Prevention Roller Cover.
Note:
Make sure to close the Double-feed Prevention
Make sure to close the Double-feed Prevention
Roller Cover tightly, by pressing both ends of
the cover.
(7) Close the ADF Door slowly until it clicks into place.
(See 7.2.3.)
(See 7.2.3.)
(8) After installing the Feed Tray, plug the AC Adaptor into the
scanner, and then push the Power Switch to turn on the
scanner.
scanner, and then push the Power Switch to turn on the
scanner.
Note:
After replacing the above Paper Feed Roller and
After replacing the above Paper Feed Roller and
Double-feed Prevention Roller, execute “Clear Counter”
for replacing roller with Service Utility. (See 9.3.4.)
Click on the first or last page to see other KV-S1045C service manuals if exist.