9.19.3. Removing the Width sensor
1. Disconnect the all the Connectors on the Main PCB.
2. Cut the Cable tie T30R, T18S binding each Lead wires.
3. Remove four screws on the Main PCB install stand.
4. Cut the Cable tie T30R on the Width sensor install stand.
5. Remove two Width sensor install screws.
6. Remove the Snap pin on the Width sensor plate.
Caution in installing
• When you install Lead wires with Cable ties, operate the
Massage mechanism block in the Intensity-strong/weak
directions to check if the Lead wires are not tense or
hooked.
• Pass the Connecting cord for Width sensor through the Pro-
tection tube, and install the tube with the Connecting cord for
Tapping motor by the Cable tie T30R. Bind them on the
white tape.
(If they are not bound properly, the Wires can get caught in
the Intensity gear and the pinion.)