9.19.2. Removing the Intensity sensor
1. Disconnect the Connector (CN103) on the Main PCB.
2. Cut the Cable tie T30R x 2, T18S x 1, which bind the Lead wires.
3. Remove the Install screw on the Massage block frame and the Intensity sensor install stand.
Caution in installing
• The Massage block frame and the Intensity sensor should be installed firmly.
(Otherwise, it leads to the overrun in the direction of the Strong.)
• When installing each Lead wires with Cable ties check if Lead wires are not abnormally pulled or hooked operating the Massage
mechanism block in the directions of strong or weak.
(Pay special attention on the *1, because the Wire moves in the operation.)