1.3 Failure diagnosis table
Sympton
Check point
Remedy
Upper heater does not turn on
electricity.
Check conduction of the power cord. (Breaking)
●   
Replace the power cord.
●   
Measure the resistance of the upper heater.
●   
Replace the upper heater.
●   
Check the joint of the lead wire. (Screw, Solder)
●   
Inspect and repair the joint.
●   
Lower heater does not turn on
electricity.
Check conduction of the power cord. (Breaking)
●   
Replace the power cord.
●   
Measure the resistance of the lower heater.
●   
Replace the lower heater.
●   
Check the joint of the lead wire. (Screw, Solder Fasten terminal)
●   
Inspect and repair the joint.
●   
Neither the upper heater nor the
lower heater turns on electricity.
Check conduction of the power cord. (Breaking)
●   
Replace the power cord.
●   
Check conduction of the timer. (Malfunction of conduction)
●   
Inspect and replace the timer.
●   
Measure the resistance of the upper and lower heaters.
●   
Replace the upper and lower heaters.
●   
Cooked food burns badly.
Thermostat does not work. (Short circuit of thermostat)
●   
Replace the thermostat.
●   
Timer stops before completion.
●   
Replace the timer.
●   