NN-SD381SZPE, NN-SD361MZPE - Panasonic Home Appliance Service Manual (repair manual). Page 10

Read Panasonic NN-SD381SZPE / NN-SD361MZPE Service Manual online

6.1. Magnetron
 1. Discharge the high voltage capacitor.
 2. Remove 1 screw holding front plate bracket on cavity top
plate.
 3. Remove 2 screws holding air guide A on cavity top plate
and on magnetron.
 4. Remove 1 screw holding air guide A on the wave guide,
then remove the air guide A.
 5. Remove 1 screw holding thermistor on the magnetron.
 6. Remove 2 screws holding the magnetron.
NOTE:
After replacement of the magnetron,tighten mounting
screws properly, making sure there is no gap between
the
waveguide
and
the
magnetron
to
prevent
microwave leakage.
CAUTION
When replacing the magnetron, be sure the antenna gasket is in
place.
6.2. Digital programmer circuit
(D.P.C)
CAUTION:
Be sure to ground any static electric charge built up in
your body before handling the D.P.C..
 1. Disconnect all connectors from D.P.C. board.
6 DISASSEMBLY AND PARTS REPLACEMENT