 9. Tighten 2 mounting screws.
Be sure the gap between door E and cavity front plate will
be 0.3~0.7mm.
NOTE:
Always perform the microwave leakage measurement
test after installation and adjustment of door assembly.
6.6. Turntable motor
 1. Remove the motor cover by breaking off at the 4 spots
indicated by arrows with a cutter or the like.
NOTE:
After removing the motor cover, be sure that cut
portions are properly trimmed off or bent to the
inside so that no sharp edges will be exposed to
outside.
 2. Disconnect 2 lead wires connected to the turntable motor.
 3. Remove the turntable motor by removing 1 screw.
NOTE:
After reinstalling the new turntable motor and
reconnecting the 2 lead wires, reinstall the motor
cover by rotating it around 180°, tucking the 2 tabs
under the base into the 2 provided slots, then screw
the single tab to the base using a 4mm x 6mm
screw.