Read Panasonic NN-DS592MZPE Service Manual online
To remove dial
Insert the ruler (wrapped with a glove) as a lever to release
the dial.
the dial.
6.4. Low voltage transformer
and/or power relays
CAUTION:
Be sure to ground any static electric charge built up in
your body before handling the DPC.
your body before handling the DPC.
1. Using solder wick or a desoldering tool and 30W soldering
iron carefully remove all solder from the terminal pins of the
low voltage transformer and/or power relays.
NOTE:
low voltage transformer and/or power relays.
NOTE:
Do not use a soldering iron or desoldering tool of
more than 30 watts on D.P.C. contacts.
more than 30 watts on D.P.C. contacts.
2. With all the terminal pins cleaned and separated from
D.P.C. contacts, remove the defective transformer/power
relays, Replace components making sure all terminal pins
are inserted completely resolder all terminal contacts
carefully.
relays, Replace components making sure all terminal pins
are inserted completely resolder all terminal contacts
carefully.