5.4. When parts must be replaced,
remove the power plug from
the outlet.
5.5. When the 10 Amp fuse is
blown due to the malfunction
of short switch:
WARNING
When the 10 Amp fuse is blown due to malfunction of the short
switch, you must replace all of the components (Primary latch switch,
Secondary switch, Short switch and Power relay B (RY1)).
 1. This
is
mandatory.
Refer
to
“Measurement
and
Adjustments” for the location these switches.
 2. When replacing the fuse, confirm that it has the appropriate
rating for these models.
 3. When replacing faulty switches, be sure the mounting tabs
are not bent, broken or deficient in their ability to hold the
switches.
5.6. Avoid inserting nails, wire, etc.
through any holes in the unit
during operation.
Never insert a wire, nail or any other metal object through the
lamp holes on the cavity or any other holes or gaps, because
such objects may work as an antenna and cause microwave
leakage.
5.7. Confirm after repair
 1. After repair or replacement of parts, make sure that the
screws of the oven, etc. are neither loose nor missing.
Microwaves might leak if screws are not properly tightened.
 2. Make sure that all electrical connections are tight before
inserting the plug into the wall outlet.
 3. Check for microwave energy leakage. (Refer to procedure
for measuring microwave evergy leakage.)
CAUTION
MICROWAVE RADIATION
USE CAUTION NOT TO BECOME EXPOSED TO RADIATION
FROM THE MICROWAVE MAGNETRON OR OTHER PARTS
CONDUCTING MICROWAVE ENERGY.
IMPORTANT NOTICE
1.The following components have potentials above 2000V while the
appliance is operated.
* Magnetron
* High voltage transformer
* High voltage diode
* High voltage capacitor
Pay special attention to these areas.
2.When the appliance is operated with the door hinge or magnetron
adjusted incorrectly, the microwave leakage can exceed more than
5mW/cm
2
. After repair or exchange, it is very important to check that
magnetron and the door hinge is correctly installed.