NC-PH22WTW, NC-PH30WTW - Panasonic Home Appliance Service Manual (repair manual). Page 27

Read Panasonic NC-PH22WTW / NC-PH30WTW Service Manual online

- 27 -
NC-PH22, NC-PH30
Peg frame
Thermistor assy
Control unit A (Bottom)
Positive lock
connector
with stopper
Thermal fuse comp.
Lead wire E assy
Control unit B (operation)
Positive lock connector with stopper
Container comp.
(With built-in boiling and
 keep warm heaters)
7.2 Basic wiring diagram
Otherwise the lead wires may contact
the components nearby to causing
failure or electric shock.
After the repair, recover the original
wire layout.
 
CAUTION
              
Power cord
Page of 33
Display