2.1.4.
TRA(+) BIAS (Transfer(+) BIAS)/TRA(-) BIAS (Transfer(-) BIAS) Unit
[Changed from original section “7.15.3. TRA(+) BIAS (Transfer(+) BIAS)/TRA(-) BIAS (Transfer(-) BIAS) Unit”]
7.15.4. TRA(+) BIAS (Transfer(+) BIAS)/TRA(-) BIAS (Transfer(-) BIAS) Unit
When CHG REM is “L” and TRA CLK is “open”, Charge BIAS(180
PA) is output from CHG OUTPUT, and at the same time Trans-
fer(+)BIAS(800V) is output from TRA OUTPUT. When 5.425kHz PWM(Plus Width Modulation) signal is input to TRA CLK through
transistor Q208, Transfer(-) CURRENT BIAS corresponding to PWM signal is output from TRA OUTPUT.