1.4.
How to Discharge the E. Capacitor on Capacitor P.C.B. Unit
CAUTION:
1. Be sure to discharge the E. Capacitor on CAPACITOR P.C.B. UNIT.
2. Be careful of the high voltage circuit on CAPACITOR P.C.B. UNIT when servicing.
2. Be careful of the high voltage circuit on CAPACITOR P.C.B. UNIT when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and remove the necessary parts/unit.
2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1k
2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1k
Ω /5W).
(An equivalent type of resistor may be used.)
3. Put the resistor between both terminals of E. Capacitor on CAPACITOR P.C.B. UNIT for approx. 5 seconds.
4. After discharging, confirm that the E. Capacitor voltage is lower than 10V by using a voltmeter.
4. After discharging, confirm that the E. Capacitor voltage is lower than 10V by using a voltmeter.
Fig. F1