3.2.1.2.
About Mount Box Unit (Ref. 16)
1. This Service Manual does not contain the following repair service information for "MOUNT BOX UNIT"(Ref.16), because it
requires special facilities and equipment.
a. Schematic diagram, Block diagram and P.C.B. layout.
b. Parts list for individual parts.
2. If the "MOUNT BOX UNIT" is confirmed as defective, exchange the "MOUNT BOX UNIT" as a unit (supplied as service parts
size).
3. Before exchanging the "MOUNT BOX UNIT", the performances must be carefully checked, by following the "7.Troubleshoot-
ing Guide" section of this service manual.
Important:
1. After replacing the MOUNT BOX UNIT, the mount box data has to be stored to the unit.
The mount box unit supplied as service parts has affix the label of own configure data.
By inputting these data into the adjustment software and writting these data to VENUS FHD (IC6001), the shutter adjustment
becomes needless.
In addition, the adjustment software can read data encoded to QR code by using WEB camera with a close-up function.
Refer to the adjustment instruction in the adjustment software for details.
Fig. S2
2. The full adjustment must be performed after replacing the "MOUNT BOX UNIT", otherwise picture quality can not be meet
with specification.
3.2.1.3.
About Flexible Cable and Connector
Do not touch carelessly so that the foreign body should not adhere to the terminal part of flexible cable and connector.
Wipe off with a clean cloth and the cotton bud, etc. when the terminal part is dirty.
3.2.1.4.
About Main P.C.B. (Ref. 1) / LCD IF P.C.B. (Ref. 40)
1. This Service Manual does not contain the following repair service information for “MAIN P.C.B.”(Ref.1) and “LCD IF
P.C.B.”(Ref.40), because it requires special facilities and equipment.
a. Schematic diagram, Block diagram and P.C.B. layout.
b. Parts list for individual parts.
2. When a part replacement is required for repairing “MAIN P.C.B.” and “LCD IF P.C.B.”, replace as an assembled P.C.B. parts.
As for handling the defected P.C.B.s, contact the sales company service depart.
*MAIN P.C.B. (VEP56135A: PP/PC/EE/GC/GD/GH/GK/GN/GT)
*MAIN P.C.B. (VEP56135B: EB/EC/EG)
*LCD IF P.C.B. (VEP59096A)
Important (About Main P.C.B.):
1. Before exchange the "MAIN P.C.B.", the performances must be carefully checked, by following the "7.Troubleshooting Guide"
section of this service manual.
2. Before replacing the "MAIN P.C.B.", proceed the EEPROM data backup from the unit. After replacing the MAIN P.C.B., over-
write the EEPROM data with backup data from the unit first, then proceed the adjustment /inspection.
If it is impossible to make a data backup due to the unit does not turns on the power and so on, additional adjustment (using
the light box) is required.
Refer to the adjustment instruction in the adjustment software for details.
3. The full adjustment must be performed after replacing the "MAIN P.C.B.", otherwise Picture quality can not be meet with spec-
ification.