WV-NW470S, WV-NW474SE - Panasonic Video Monitoring Service Manual (repair manual). Page 17

Read Panasonic WV-NW470S / WV-NW474SE Service Manual online

2-9
cy
g
M
G
Y
L
yl
B
b
G
C
Y
dG
10
°
0
°
10
°
100%
75%
R
V
U
mg
r
20%
20%
dG
Red
        
±
 2˚
220 % 
±
 5 %
Phase
Gain
Yellow
        
±
 5˚
120 % 
±
 5 %
108˚
165˚
(10.2). 5 100°K B Gain Adjustment
Test Point:
Video Output Connector
8
Keep the Colour Temperature at 5 100°K.
8
Adjust data with the ARROW keys so that the Yellow gain
becomes 120 % ± 5 %.
8
Repeat adjusment steps (10.1) and  (10.2) until both
Chrominance phase and gain are adjusted to proper posi-
tion as shown in Fig. 5-13 and Table 5-3.
Fig. 5-13
Table 5-3
Minimize
Chrominance
Level
Fig. 5-14
8
Press ENTER key for next adjustment.
(11).High light Chroma Clip Adjustment
Test Point:
Video Output Connector
Adjust:
RAM (801F)
8
Return the Colour Temperature from 5 100°K to 3 200°K
by removing the Colour Temperature Conversion Filter
from the Lens.
8
Aim the Camera at the White Chart or White Paper.
8
Connect the terminated Oscilloscope with 75 
to the
Video Output Connector.
8
Adjust data with the ARROW keys so that the false
chrominance level becomes minimum as shown in Fig. 5-
14
Note: The Data of 801F should be adjusted from FF, the first
minimum point of the false chrominance signal is 
adjusting point.
(12.1). Line Lock Phase Coarse Adjustment
Test Point:
Video Output Connector
Live (Brown) of the Power Cable
8
Change the Colour Temperature from 3 200°K to 5 100°K
by mounting the Colour Temperature Conversion Filter on
the Lens.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the CH1 of the terminated Oscilloscope with 75
to the Video Output Connector.
8
Connect the CH2 of the Oscilloscope to the Live (Brown)
of the Power Cable.
8
Connect the Ground Probe of CH2 to the Neutral (Blue)
of the Power Cable.
8
Adjust data with the ARROW keys so that the Decay
point of V SYNC signal gains 2H ± 2H from the zero-
cross point of the AC Power Line Input Waveforms as
shown in Fig. 5-15.
8
Press the ENTER key for next adjustment.
(12.2). Line Lock Phase Fine Adjustment
Test Point:
Video Output Connector
Live (Brown) of the Power Cable
8
Keep the Colour Temperature at 5 100°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the CH1 of the terminated Oscilloscope with 75
to the Video Output Connector.
8
Connect the CH2 of the Oscilloscope to the Live (Brown)
of the Power Cable.
8
Connect the Ground Probe of CH2 to the Neutral (Blue)
of the Power Cable.
8
Adjust data with the ARROW keys so that the Decay
point of V SYNC signal gains 2H ± 2H from the zero-
cross point of the AC Power Line Input Waveforms as
shown in Fig. 5-15.
8
Repeat adjustment steps (12.1) and  (12.2) until the
Decay point of V SYNC signal gains 2H ± 2H from the
zero-cross point of the AC Power Line Input waveforms.
8
After completing the adjustment, press the QUIT (F3)
key, then the menu <SAVE CAMERA DATA TO FILE : 
✽ ✽  
. EVR? Y/N> will be displayed.
8
Press the key, and then press the ENTER key to finish
this adjustment procedure.
AC Power
Line Input
Waveforms
(CH2)
Video Output
Signal
Waveform
(CH1)
+
2H 
±
 2H
Zero-Cross Point
V SYNC
(NEUTRAL)
(LIVE)
Fig. 5-15
Page of 54
Display

Click on the first or last page to see other WV-NW470S / WV-NW474SE service manuals if exist.