WV-NP472E - Panasonic Video Monitoring Service Manual (repair manual). Page 14

Read Panasonic WV-NP472E Service Manual online

– 11 –
Minimize
Chrominance
Level
Fig. 4-13
(11).High light Chroma Clip Adjustment
Test Point:
CN403 (Video Output Connector)
I/F Power Board
Adjust:
RAM (801F)
8
Return the Colour Temperature from 5 100°K to 3 200°K
by removing the Colour Temperature Conversion Filter
from the Lens.
8
Aim the Camera at the White Chart or White Paper.
8
Connect the terminated Oscilloscope with 75 
to the
Video Output Connector.
8
Adjust data with the ARROW keys so that the false
chrominance level becomes minimum as shown in Fig. 4-
13.
Note: The Data of 801F should be adjusted from FF, the first
minimum point of the false chrominance signal is 
adjusting point.
8
After completing the adjustment, press the QUIT (F3)
key, then the menu <SAVE CAMERA DATA TO FILE : 
✽ ✽  
. EVR? Y/N> will be displayed.
8
Press the key, and then press the ENTER key to finish
this adjustment procedure.