Read Panasonic WV-NP472E Service Manual online
– 11 –
Minimize
Chrominance
Level
Chrominance
Level
Fig. 4-13
(11).High light Chroma Clip Adjustment
Test Point:
CN403 (Video Output Connector)
I/F Power Board
Adjust:
RAM (801F)
8
Return the Colour Temperature from 5 100°K to 3 200°K
by removing the Colour Temperature Conversion Filter
from the Lens.
by removing the Colour Temperature Conversion Filter
from the Lens.
8
Aim the Camera at the White Chart or White Paper.
8
Connect the terminated Oscilloscope with 75
Ω
to the
Video Output Connector.
8
Adjust data with the ARROW keys so that the false
chrominance level becomes minimum as shown in Fig. 4-
13.
chrominance level becomes minimum as shown in Fig. 4-
13.
Note: The Data of 801F should be adjusted from FF, the first
minimum point of the false chrominance signal is
adjusting point.
adjusting point.
8
After completing the adjustment, press the QUIT (F3)
key, then the menu <SAVE CAMERA DATA TO FILE :
key, then the menu <SAVE CAMERA DATA TO FILE :
✽
✽ ✽
. EVR? Y/N> will be displayed.
8
Press the N key, and then press the ENTER key to finish
this adjustment procedure.
this adjustment procedure.
Click on the first or last page to see other WV-NP472E service manuals if exist.