WV-CPR470, WV-CPR474E - Panasonic Video Monitoring Service Manual Simplified (repair manual). Page 5

Read Panasonic WV-CPR470 / WV-CPR474E Service Manual Simplified online

2-1
ADJUSTMENT PROCEDURE
3. Connection and Setting Up for
Adjustment
3.2.Setting Up for Remote E.V.R. 
Adjustment Kit
(3). Installing E.V.R. Adjustment Program 
8
Make a copy of following necessory files to your comput-
er from original floppy disk of the Remote E.V.R.
Adjustment Kit.
RADJ2.EXE
CPR470E.SEQ
CPR470E.EV2
(4). Procedure
1. Confirm that the CONFIG.SYS file on your computer
contains DEVICE=ANSI.SYS.
2. Insert floppy disk containing E.V.R.adjustment
program into your floppy drive (for example,drive:A)
and type A:
3. At the prompt, type CD IBMPC and press ENTER key.
4. Type COPY RADJ2.EXE B: and press ENTER key.
5. Type CD\ and press ENTER key.
6. Type CD SEQ and press ENTER key.
7. Type COPY CPR470E.SEQ B: and press ENTER key.
8. Type CD\ and press ENTER key.
9. Type CD EVR and press ENTER key.
10. Type COPY CPR470E.EV2 B: and press ENTER key.
11. After completing installation of program, you are ready
to use the E.V.R. adjustment program.
3.3.Setting Up
8
An initial setting of the Switch on the Left side Panel of
the WV-CPR470 and WV-CPR474E as follows:
DIP Switch (SW7 on the I/F Boad)
SW1: 
Gen-Lock Line Termination ON (75 
) / OFF (Open)
(Hi-Z, G/L 75
) ................................................G/L 75
SW2:
RS-485 Line Termination ON (150
) / OFF (Open)
(Hi-Z, RS485 LINE TERM) .............RS485 LINE TERM
SW3-5:
RS485 2-Line (Half-Duplex) / 4-Line (Full-Duplex) Selection
(4-LINE, 2-LINE).................................................4-LINE
8
The adjustments should be done with this initial setting,
unless otherwise specified.
8
The adjustments should be done after 10 minutes warm
up.
4. Adjustment Procedure
4.2.Adjustment Procedure-2
(E.V.R. Adjustment)
8
Mount the ALC Lens WV-LA9C3B on the Camera.
8
Insert new disk containing the E.V.R. Adjustment pro-
gram into IBM PC/AT and turn on the Power Switch of
IBM PC/AT.
8
To change communication mode of the camera, turn off
the power for the camera.
8
Turn on the power for the camera while pressing both
Left and Right Buttons on the Left side panel of the
camera.  
8
When starting an adjustment, at the prompt, type
RADJ2 CPR470E and press the ENTER key, an initial
menu will be displayed in Table 4-1.
8
Press the SAVE(F5) key of the Computer, then the
Computer will ask you for the file name.
8
Type  xxxxxxxx.EV2 0 2FF. Give an appropriate file
name for xxxxxxxx within 8 letters, but do not use
CPR470E.
8
Press the ENTER key.
8
This saving procedure is recommended to keep the cur-
rent adjustment status of the Camera.
8
Press the LOAD(F1) key and type CPR470E.EV2  and
press the ENTER key for presetting adjustment of the
Camera.
Table 4-1
PANASONIC REMOTE EVR ADJUSTMENT SYSTEM CCTV PRODUCT:CP470 EEPROM:0
✽   ✽   ✽   ✽   ✽   ✽   ✽  ✽   ✽  ✽   ✽  ✽  ✽   ✽   ✽   ✽   ✽   ✽  ✽  ✽  ✽  ✽  ✽ 
MENU
✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽   ✽    ✽   ✽   ✽   
Page (1/1)
✽   ✽   ✽  ✽   ✽  
PAL
1. SC FREQUENCY
1.1. VS SC FREQUENCY
2. HI CLIP LEVEL
3. ALC DC
4. VIDEO OUT GAIN 
5. PEDESTAL
6.1. BURST LEVEL
6.2. BURST LEVEL
6.3. BURST LEVEL
6.4. BURST LEVEL
7.1. WB 3200K MANU OFFSET R
7.2. WB 3200K MANU OFFSET B
8.1. WB 6500K ATW LIMIT R
8.2. WB 6500K ATW LIMIT B
9.1. 3200K  R_GAIN
9.2. 3200K  B_GAIN
9.3. 3200K  MATRIX
10.1. 5100K  R_GAIN
10.2. 5100K  B_GAIN
11. HIGH LIGHT CHROMA CLIP
12.1. LL ADJUSTMENT1
12.2. LL ADJUSTMENT2
<CONTENTS> 17.73447 Mz ± 40Hz 
<INSTRUCTION> PLEASE CHOOSE MENU DATA BY ARROW-KEY
LOAD (F1)          QUIT (F3)             SAVE (F5)
Note:
8
Adjustment items are exactly same as WV-CP470/WV-
CP474E.
8
Defference is just file name.
8
Please kindly refer to the Original Service Manual WV-
CP470/WV-CP474E for the rest.
Page of 20