WV-CL920A, WV-CL924A - Panasonic Video Monitoring Service Manual (repair manual). Page 5

Read Panasonic WV-CL920A / WV-CL924A Service Manual online

1-1
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
<WV-CL920A>
<WV-CL924A>
WV-
CL920A
FB
LOCK
FB
LOCK
Hi-Z G/L 75
WV-
CL920A
VIDEO OUT
GEN-LOCK
AC 24V
IN
DC 12V
IN
GND
2
1
r
e
!3
!3
!2
!2
!1
q
w
!0
i
y
t
u
o
!6
!4
!5
!7
VIDEO OUT
GEN-LOCK
GND
120V  AC  60Hz
OUT
ALARM
DAY/
NIGHT
GND
IN
GND
OUT
ALARM
DAY/
NIGHT
GND
IN
Slide the panel to the left until it locks.
q
Auto Iris Lens Connector
This connector is used to connect the auto iris lens with a 4-
pin male connector supplied as a standard accessory (Part
No. YWM1943A).
w
Flange-back Adjusting Ring (FB)
This ring is used to adjust the back focal length or picture
focus. Rotate this ring upward or downward for a CS-mount
lens. In case of using a C-mount lens, adjust it with the C-
mount adapter.
e
Lens (Option)
r
Focus Fixing Screw (LOCK)
t
Camera Mounting Screw Hole
This hole is used to mount the camera onto a mounting
bracket.
y
Down Button (
)
This button is used to move the cursor downward. It is also
used to select items in the CAM SET UP menu.
u
Right Button (
)
This button is used to move the cursor to the right. It is also
used to select the mode and can be used to adjust some
levels.
i
Left Button (
)
This button is used to move the cursor to the left. It is also
used to select the mode and can be used to adjust some
levels.
o
Up Button (
)
This button is used to move the cursor upward. It is also
used to select items in the CAM SET UP menu.
!0
Set Button (
)
This button is used to activate an item selected in the CAM
SET UP menu.
!1
Gen-lock Termination Switch (Hi-Z, G/L 75
)
Set this switch to Hi-Z when a gen-lock video input signal is
looped through. In all other cases, set this switch to 75 
.
!2
Gen-lock Input Connector (GEN-LOCK)
This connector is used to connect an external system for
synchronization.
!3
Video Output Connector (VIDEO OUT)
This connector is used to connect with the VIDEO IN con-
nector of the monitor.
!4
Alarm Output Terminal (ALARM OUT, GND)
Connects to the alarm input connector (terminal) of an exter-
nal device. When the camera detects motion, the alarm out-
put signal is supplied to the connected external device
(Open collector output: 16 V DC, 100 mA max).
!5
Day/Night Input Terminal (DAY/NIGHT IN, GND)
This terminal is used for connecting the camera to an exter-
nal day/night detecting sensor.
!6
AC Inlet Socket
Plug the power cord (supplied as a standard accessory) into
this socket and connect it to an AC outlet.
!7
AC/DC Compatible Input Terminal
(DC 12V IN/AC 24V IN, GND)
This terminal is for connecting the 12 V DC or 24 V AC
power supply cord.
Caution: Connect to 12 V DC (10.8 V-16 V) or 24 V AC
(19.5 V-28 V) class 2 power supply only. Be sure to con-
nect the grounding lead to the GND terminal when the
power is supplied from a 24 V AC power source.
Page of 33