WR-210E - Panasonic Video Monitoring Service Manual (repair manual)

wr-210e service manual
Model
WR-210E
Pages
10
Size
668.64 KB
Type
PDF
Document
Service Manual
Brand
Device
Video Monitoring / REMOTE CONTROL MIC
File
wr-210e.pdf
Date

Read Panasonic WR-210E Service Manual online

ORDER NO. AVS0308506C3
Remote Control Mic
WR-210E
BUS
Y
LIN
E
ON A
IR
POW
ER
C
MIC
ANNOUNCE
C SIGN
SPECIFICATIONS
Power supply:
24 V DC, 45 mA or less (screwless terminals)
Frequency characteristic:
50-15000 Hz ± 3 dBV (1000 Hz reference) at line input
Distortion factor:
1 % or less (at 1000 Hz)
S/N ratio:
50 dBV or more
Audio input:
Flexible microphone: –55 dBV, 600 
unbalanced, AGC equipped, one circuit 
(volume adjustment: semi-fixed)
Business input: –2 dBV, 10 k
unbalanced, one circuit 
(volume adjustment: semi-fixed), large size tip-sleeve phone jack
Audio output:
H, C, 0 dBV, 600 
balanced, one circuit, load impedance 300 
or more, connection terminals
Record output: 0 dBV, 10 k
unbalanced, one circuit, large size tip-sleeve phone jack
Operation switch:
Announcement x 1, channel x 10, c x 1, c sign (up/down) x 2, microphone switch x 1, 
line input switch x 1
Display:
power, on air, busy
Control output:
Announcement control: one circuit, connection terminals, switch output, 
max. control capacity 30 V DC 50 mA
System control: 1-10 circuits, connection terminals, switch output, 
max. control capacity 30 V DC 50 mA
C sign control up/down: one circuit, connection terminals, switch output, 
max. control capacity 30 V DC 50 mA
Priority control: priority input, priority output
2 0 0 3
M a t s u s h i t a   E l e c t r i c   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
The  Product  with  PbF
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within 
the unit may have sufficient magnitude to cause electric 
shock. Therefore, it is dangerous to make any kind of contact 
with any inside part of this unit.
This symbol alerts the user that important literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by the ”
 
Y
 
” mark on the schematic diagram and the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About  Lead  Free  Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35 
°
C – 40 
°
C
(95 
°
F – 104 
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360 
°
C – 370 
°
C
(680 
°
F – 698 
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600 
°
C / 1112 
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
   WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the 
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to 
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any 
attempt to service or repair the product or products dealt with in this service information by anyone else could 
result in serious injury or death.
Microphone:
Electret-condenser type (windshield equipped), sensitivity –70 dBV, output impedance 2.2 k
,
unidirectional type
Dimensions:
250 (W) x 50 (H) x 155 (D) mm (projections and flexible microphone excluded)
Weight:
700 g
Finishing:
Top case: resin, OA ivory coloured (Munsell value 5.5Y7.5/0.3 approximate colour)
Bottom case: resin, grey coloured (Munsell value N5.5 approximate colour)
STANDARD ACCESSORIES
Operating Instructions ............................................................................. 1 pc.
Binding band  ........................................................................................... 1 pc.
Windshield .............................................................................................. 1 pc.
CONTENTS
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS............................................................. 1
ADJUSTMENT PROCEDURE ............................................................................................................... 2
SCHEMATIC DIAGRAM .........................................................................................................................3
CONDUCTOR VIEW ..............................................................................................................................4
EXPLODED VIEW...................................................................................................................................5
REPLACEMENT PARTS LIST  ............................................................................................................. 6
- 1 -
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
q
Flexible microphone
You can aim the microphone at your favorite direction.
w
Busy indicator (BUSY)
For priority announcement, this indicator lights up dur-
ing public address is performed through other remote
control microphones. However, when the individual pri-
ority function is active, the indicators of higher priority
microphones do not light up during public address is
performed through a lower priority microphone.
e
On air indicator (ON AIR)
Lights up during public address is performed with this
unit.
r
Power indicator (POWER)
Lights up during 24 V DC is supplied to this unit.
t
Line switch (LINE)
When announcing an audio program from the device
connected to the line input, press this switch. 
y
All call switch (ALL CALL)
When making an announcement to all blocks in unison
from this unit, press this switch. It is not necessary to
press the announcement switch to make an announce-
ment in unison.
u
Call sign switch (
T
T
CALL SIGN
T
T
)
Makes the device connected to this unit (an emergency
public address system or a business public address
system) sound a call sign.
Note:
Do not press the call sign up and down switches
simultaneously. Failure to observe this activates the
status of an announcement in unison.
i
Announcement switch (ANNOUNCE)
When making an announcement with this unit, press
this switch. If you press this switch again, the
announcement will be finished.
o
Microphone switch (MIC)
When making an announcement through the flexible
microphone, press this switch.
!0
Individual switches (1-10)
When making an announcement to a specific block,
press the corresponding switch.
!1
Line input (–2 dBV, 10 k
unbalanced)
Is connected to the audio output of an external line
device. 
!2
Connection terminals 
Are connected to emergency public address systems
(wall-mounted type/rack type) or business public
address systems.
!3
Record output (0 dBV, 10 k
unbalanced)
Is used when recording audio from the microphone of
this unit or a line device.
!4
Cable clamp
Is used when securing cables with the binding band
(supplied).
Front panel
Remote Control Mic   WR-210
BUSY
LINE
ON AIR
POWER
1
2
3
4
5
6
7
8
9
10
ALL CALL
CALL SIGN
MIC
ANNOUNCE
q
w
e
r
t
y
u
i
o
!0
Rear panel
!4
!1
!2
!3
REC OUT
LINE IN
STRIPPING LENGTH 11mm
0dBV
-2dBV  10k
COM
C
24V
0V
CKO  CONT
C
2
1
3
4
5
6
7
8
9
10
11mm
H
OUT IN
DOWN
UP
(0V)
LINE OUT
DC
PRIORITY
CALL SIGN
ACCEPTABLE WIRE GAGE
SOLID WIREø
0.4 (AWG26)~
ø1.2 (AWG16)
STRANDED WIRE0.3mm
2
~1.25mm
(AWG16ELEMENT WIREø
0.18MIN)
Page of 10
Display

Download Panasonic WR-210E Service Manual (Repair Manual)

Here you can read online and download Panasonic WR-210E Service Manual in PDF. WR-210E service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic WR-210E Video Monitoring. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.