WJ-SX150, WJ-SX150A - Panasonic Video Monitoring Service Manual (repair manual). Page 7

Read Panasonic WJ-SX150 / WJ-SX150A Service Manual online

– 2-1 –
DIFFERENCE BETWEEN WJ-SX150 AND WJ-SX150A
No.
Category
Item
WJ-SX150
WJ-SX150A
1
Function
Master-Slave Connection
N/A
Yes
2
Function
Maximum Camera Connection
16
16 (by 1 unit), 28 (by 2units) ,40 (by 3 units), 
52 (by 4 units), 64 (by 5 units)
3
Function
Connection with WJ-HD200
N/A
Yes
4
SETUP MENU
Master-Slave
N/A
Yes
Administrator Console   
5
SETUP MENU
LCN (Logical Camera Number)
N/A (Fixed to 1-16)
1-99 (Variable)
Administrator Console   
6
SETUP MENU
Tour SEQ
16 steps x 16 patterns
64 steps x 32 patterns
Administrator Console   
7
SETUP MENU
Timer Event
30 events
50 events
 
Administrator Console   
8
SETUP MENU
Alarm Event
16 events
99 events
 
Administrator Console   
9
SETUP MENU
Alarm No. assignment to Alarm port pin
Not variable
Variable
Administrator Console   
10
SETUP MENU 
Controller Name
DATA1-4
Terminal_K1-K4
Administrator Console   
11
SETUP MENU
HD200
N/A
Yes
Administrator Console (Recorder selection item)  
12
Front Panel
Unit Number Selector
1 (Fix)
0 (Normal, Master), 1-4 (Slave)
13
Standard Accessories Cross Cable
None
1
14
Operation
Recoder Selection
[RECORDER]
[0] –> [RECORDER] : Master Recorder
(from Terminal Mode Control Unit.)
[1] –> [RECORDER] : Slave 1 Recorder
[2] –> [RECORDER] : Slave 2 Recorder
[3] –> [RECORDER] : Slave 3 Recorder
[4] –> [RECORDER] : Slave 4 Recorder
15
Operation
Recoder Selection
[1] [1] [1] [CAM]
[1] [0] [0] [CAM] : Master Recorder
(from PS    DATA Control Unit.)
[1] [0] [1] [CAM] : Slave 1 Recorder
[1] [0] [2] [CAM] : Slave 2 Recorder
[1] [0] [3] [CAM] : Slave 3 Recorder
[1] [0] [4] [CAM] : Slave 4 Recorder
8
Page of 55
Display

Click on the first or last page to see other WJ-SX150 / WJ-SX150A service manuals if exist.