CAMERA MECHANICAL ASS'Y REPLACEMENT PROCEDURE
1. Removal of the Camera Mechanical Ass'y
(1).Turn off the power of the Control Unit BM-ED500.
When supplied the power from the External DC Power
Supply Unit, turn off the power of the External DC Power
Supply Unit.
Supply Unit, turn off the power of the External DC Power
Supply Unit.
(2).Referring to Fig. 1, open the 10-key Cover, remove two
tamperproof screws (with the supplied Screw Driver
Tool) that secure the 10-key Unit and remove the 10-key
Unit from the BM-ET500.
Tool) that secure the 10-key Unit and remove the 10-key
Unit from the BM-ET500.
Fig. 1
(3).Referring to Fig. 2, disconnect the connector CN552 on
the 10-key Board of the 10-key Unit and remove the Wire
Ass'y (30-pin).
Ass'y (30-pin).
Fig. 2
1
2
3
4
5
6
7
8
9
0
ENTER
1
2
3
4
5
CANCEL
CANCEL
Remove two temperproof screws.
Open the 10-key Cover.
BM-ET500
BM-ET500
10-key Unit
Wire Ass'y
(30-pin)
(30-pin)
10-key Board
CN552
10-key Unit
(4).Referring to Fig. 3, disconnect the Coaxial Cable (BNC
male) of the Control Unit (Camera 1-3) from the Video
Output Cable (BNC female) .
Output Cable (BNC female) .
Fig. 3
(5).Referring to Fig. 4, disconnect the connector CN501 on
the Camera Terminal Board and remove the Video
Output Cable (for the Built-in Color (Colour) CCTV
Camera).
Output Cable (for the Built-in Color (Colour) CCTV
Camera).
Fig. 4
(6).Referring to Fig. 5, disconnect the 0V and +32V or +24V
ports of E501 on the Camera Terminal Board and
remove the Power Cable for the Control Unit or the
External DC Power Supply Unit.
remove the Power Cable for the Control Unit or the
External DC Power Supply Unit.
Fig. 5
Video Output Cable
(BNC female)
(BNC female)
Coaxial Cable (BNC male) of
the Control Unit (Camera 1-3)
the Control Unit (Camera 1-3)
Disconnect them.
Camera Terminal
Board
Board
Remove the Cable
from this hole.
from this hole.
Video Output Cable (for the
Built-in Color (Colour) CCTV
Camera)
Built-in Color (Colour) CCTV
Camera)
0 V
Camera
Terminal
Board
Terminal
Board
E501
+32 V
+24 V
Power Cable
Remove the Cable
from this hole.
from this hole.
CN501