CAMERA MECHANICAL ASS'Y REPLACEMENT PROCEDURE
1. Removal of the Camera Mechanical Ass'y
(1).Turn off the power of the Control Unit BM-ED500.
When supplied the power from the External DC Power
Supply Unit, turn off the power of the External DC Power
Supply Unit.
(2).Referring to Fig. 1, open the 10-key Cover, remove two
tamperproof screws (with the supplied Screw Driver
Tool) that secure the 10-key Unit and remove  the 10-key
Unit from the BM-ET500.
Fig. 1
(3).Referring to Fig. 2, disconnect the connector CN552 on
the 10-key Board of the 10-key Unit and remove the Wire
Ass'y (30-pin).
Fig. 2
1
2
3
4
5
6
7
8
9
0
ENTER
1
2
3
4
5
CANCEL
CANCEL
Remove two temperproof screws.
Open the 10-key Cover.
BM-ET500
BM-ET500
10-key Unit
Wire Ass'y
(30-pin)
10-key Board
CN552
10-key Unit
(4).Referring to Fig. 3, disconnect the Coaxial Cable (BNC
male) of the Control Unit (Camera 1-3) from the Video
Output Cable (BNC female) .
Fig. 3
(5).Referring to Fig. 4, disconnect the connector CN501 on
the Camera Terminal Board and remove the Video
Output Cable (for the Built-in Color (Colour) CCTV
Camera).
Fig. 4
(6).Referring to Fig. 5, disconnect the 0V and +32V or +24V
ports of E501 on the Camera Terminal Board and
remove the Power Cable for the Control Unit or the
External DC Power Supply Unit.
Fig. 5
Video Output Cable
(BNC female)
Coaxial Cable (BNC male) of
the Control Unit (Camera 1-3)
Disconnect them.
Camera Terminal 
Board
Remove the Cable
from this hole.
Video Output Cable (for the
Built-in Color (Colour) CCTV
Camera)
0 V
Camera
Terminal
Board
E501
+32 V
+24 V
Power Cable
Remove the Cable 
from this hole.
CN501