BL-C210CE/BL-C210E
Operation of Pyroelectric Infrared Sensor
1. Pyroelectric Infrared Sensor (IC704) emits analogue signal, when a heat source, such as a person, moves into the detection
area.
2. Above signal is amplified by Operation Amplifier (IC703) which emits analogue signal.
3. Above signal is input to AD of CPU (IC101) and the signal amplitude exceeds the specified voltage range, a reaction occurs.
4.1.7.
LED Control Block
LED is controlled by CPU which is mounted on Main Board. Control data is input into LED Control Circuit. (Three color LED is
employed.)
GAIN1 (IC701-7pin)
GAIN2 (IC701-3pin)
GAIN
0
0
71.2
1
0
63.4
0
1
60.2
1
1
57.2
LED_R
LED_G
Color of LED
L
L
OFF
L
H
Green
H
L
Red
H
H
Orange
Page of 69
Display

Click on the first or last page to see other BL-C210CE / BL-C210E service manuals if exist.