17
8.2.
Self Diagnostic Function Error Code
8.2.1.
CD Mechanism Error Code Table
8.2.2.
Power Amp Error Code Table
 of error
Automatic FL Display
Remarks
CD H15
CD Open Abnormal
During operation 
POS_SW_R On fail to be 
detected within 4 sec. Error 
No. shall be clear by force 
or during cold start.
Press [ ] on main unit for 
next error.
CD H16
CD Closing Abnormal
During operation 
POS_SW_CEN On fail to 
be detected within 4 sec. 
Error No. shall be clear by 
force or during cold start.
Press [ ] on main unit for 
next error.
F26
Communication between 
CD servo LSI and micro-p 
abnormal.
During switch to CD func-
tion, if SENSE = “L” within 
failsafe time of 20ms.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description of error
 of error
Automatic FL Display
Remarks
F61/F76
Power Amp IC output 
SMPS NG
Checking SMPS Type
Refer to 8.3.10 for more 
information
SMPS type and REGION 
not match.
The unit will shut down.
abnormal
During power-on, PDET1, 
PDET2 & MAINV_DET / 
TEMP_DET is “L” after 1 
sec.
Press [ ] on main unit for 
next error.
Press [ ] on main unit for 
next error.
Error Code
Diagnostic Contents
Description of error