WH-SDC07F3E5, WH-SDC09F3E5, WH-UD07FE5, WH-UD09FE5 - Panasonic Air Conditioner Service Manual (repair manual). Page 14

Read Panasonic WH-SDC07F3E5 / WH-SDC09F3E5 / WH-UD07FE5 / WH-UD09FE5 Service Manual online

14 
10
Booster Heater
To activate or deactivate the water tank’s booster heater.
Note: If NO is selected, menu 11 is skipped.
YES
NO
NO
NO
B
11
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is heating up
the water tank.
 20 minutes  ~
1 hour 35 minutes
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
12
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 13 to 15 are skipped.
YES
13
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
 Monday  ~
Sunday
 0:00  ~ 23:50
14
Sterilisation Temperature
To set the temperature of sterilisation.
 40 °C  ~ 75 °C
15
Continuation of Sterilisation
To maintain heating temperature in order to complete the sterilisation.
 5 minutes  ~
 1 hour
16
Base Pan Heater
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 17 is skipped.
YES
17
Base Pan Heater type
Type A - The base pan heater activates only during deice operation.
s
i
e
r
u
t
a
r
e
p
m
e
t
t
n
e
i
b
m
a
r
o
o
d
t
u
o
n
e
h
w
s
e
t
a
v
it
c
a
r
e
t
a
e
h
n
a
p
e
s
a
b
e
h
T
-
B
e
p
y
T
5 °C or lower.
A
18
*
1,
*
2
Cool Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to change from
HEAT to COOL.
 5 °C  ~ 25 °C
19
*
1,
*
2
Heat Outdoor Temperature setting
To set the outdoor ambient temperature for the AUTO mode to change from
COOL to HEAT.
 5 °C  ~ 25 °C
20
Dry Concrete
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than during
construction.
 1 day  ~ 99 days
User
Control panel preparation
Press
.
Press
 or
 to set the current day.
Press
 to confirm.
Repeat steps  and  to set the current time.
Note:
:
w
o
l
e
b
s
e
s
a
c
n
i
t
e
s
e
b
o
t
d
e
e
n
e
m
it
d
n
a
y
a
d
t
n
e
rr
u
c
e
h
T
- When the power is turned on for the first time.
e
h
t
n
o
d
e
n
r
u
t
s
a
w
r
e
w
o
p
e
h
t
e
c
n
i
s
d
e
s
p
a
l
e
s
a
h
e
m
it
g
n
o
l
A
-
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution  Indicator (Tank Temperature above 60 °C)
Dealer
 Operation/settings to be done only by the authorised dealer/specialist.
User
 Operation/settings to be done by the authorised dealer/specialist or user.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorized installers or our authorized service partners.
*
2
Only displayed when COOL mode is unlocked (Means when COOL mode is available).
 
 
 
 
 
 
 
 