U-4LE1E5, U-4LE1E8, U-5LE1E5, U-5LE1E8, U-6LE1E5, U-6LE1E8 (serv.man2) - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic U-4LE1E5 / U-4LE1E8 / U-5LE1E5 / U-5LE1E8 / U-6LE1E5 / U-6LE1E8 (serv.man2) Service Manual online

1 - 2
Outline of Mini VRF SYSTEM
1
2
3
4
5
6
7
8
9
1. Line-up
Indoor units
Capacity: kW
(BTU/h) Cooling
/
Heating
Type
28
22
36
56
73
90
106
140
160
S-22MU1E5
S-28ML1E5
S-36ML1E5
S-56ML1E5
S-73ML1E5
S-28MD1E5
S-36MD1E5
S-56MD1E5
S-73MD1E5
S-22MP1E5
S-22MR1E5
S-28MP1E5
S-36MP1E5
S-56MP1E5
S-71MP1E5
S-28MR1E5
S-36MR1E5
S-56MR1E5
S-71MR1E5
Wall Mounted 
Type 
(K1 Type)
Wall Mounted 
Type 
(K2 Type)
Low Silhouette 
Ducted Type 
(F1 Type)
Slim Low Static 
Ducted Type 
(M1 Type)
Floor Standing 
Type 
(P1 Type)
Concealed Floor 
Standing Type 
(R1 Type) 
2.2 (7,500)
2.5 (8,500)
/
2.8 (9,600)
3.2 (11,000)
/
3.6 (12,000)
4.2 (14,000)
/
10.6 (36,000)
11.4 (39,000)
/
14.0 (47,800)
16.0 (54,600)
/
16.0 (54,600)
18.0 (61,500)
/
7.3 (25,000)
8.0 (27,000)
/
9.0 (30,000)
10.0 (34,000)
/
5.6 (19,000)
6.3 (21,000)
/
60
6.0 (20,500)
7.1 (24,200)
/
45
S-36MU1E5
S-28MU1E5
S-45MU1E5
S-36MY1E5
S-28MY1E5
S-22MY1E5
S-56MY1E5
S-45MY1E5
S-36MM1E5
S-28MM1E5
S-22MM1E5
S-56MM1E5
S-45MM1E5
S-45ML1E5
S-56MT1E5
S-36MT1E5
S-22MK1E5
S-28MK1E5
S-36MK1E5
S-22MK2E5
S-28MK2E5
S-36MK2E5
S-73MT1E5
S-106MT1E5
S-140MT1E5
S-45MT1E5
S-45MD1E5
S-28MF1E5
S-22MF1E5
S-36MF1E5
S-56MF1E5
S-73MF1E5
S-90MF1E5
S-106MF1E5
S-140MF1E5
S-160MF1E5
S-45MF1E5
S-45MP1E5
S-45MR1E5
4.5 (15,000)
5.0 (17,000)
/
S-22ML1E5
4-Way Cassette 
Type 
(U1 Type)
4-Way Cassette 
60×60 Type 
(Y1 Type)
4-Way Cassette 
60×60 Type 
(Y2 Type)
2-Way Cassette 
Type 
(L1 Type)
Ceiling Type 
(T1 Type)
1-Way Cassette 
Type (D1 Type)
S-56MU1E5
S-73MU1E5
S-106MU1E5
S-140MU1E5
S-160MU1E5
S-22MU1E51
S-36MU1E51
S-28MU1E51
S-45MU1E51
S-56MU1E51
S-60MU1E51
S-73MU1E51
S-90MU1E51
S-106MU1E51 S-140MU1E51 S-160MU1E51
Low Silhouette 
Ducted Type 
(F2 Type)
S-28MF2E5
S-22MF2E5
S-36MF2E5
S-56MF2E5
S-73MF2E5
S-90MF2E5
S-106MF2E5
S-140MF2E5
S-160MF2E5
S-45MF2E5
S-36MY2E5
S-28MY2E5
S-22MY2E5
S-56MY2E5
S-45MY2E5
S-45MK1E5
S-56MK1E5
S-73MK1E5
S-106MK1E5
S-60MF2E5
Type
73
106
140
High Static Pressure
Ducted Type
(E1 Type) 
S-73ME1E5
S-106ME1E5
S-140ME1E5
TD831155-04_MINI VRF.indb   2
TD831155-04_MINI VRF.indb   2
2014/01/07   11:46:59
2014/01/07   11:46:59
Page of 127
Display

Click on the first or last page to see other U-4LE1E5 / U-4LE1E8 / U-5LE1E5 / U-5LE1E8 / U-6LE1E5 / U-6LE1E8 (serv.man2) service manuals if exist.