Read Panasonic CW-XC51LE Service Manual online
1.1
Main Unit
Operation OFF/ON
Remote Control signal Receiving Sound
Operation Indicator Light (LED’S)
OPERA-
TION
•
Can be enable/disable by pressing down
Operation OFF/ON button for 10 seconds.
•
MODE
COOL (Green)
FAN (Orange)
Lights up in Cooling
Mode Operation.
Lights up in Fan Mode
Operation.
Mode Operation.
Lights up in Fan Mode
Operation.
•
FAN SPEED
HIGH (Orange)
MED (Orange)
LOW (Orange)
Lights up in High Fan
Speed Operation.
Lights up in Medium
Fan Speed Operation.
Lights up in Low fan
Speed Operation.
Speed Operation.
Lights up in Medium
Fan Speed Operation.
Lights up in Low fan
Speed Operation.
•
TIMER
(Orange)
Lights up in Timer
Setting.
Setting.
•
JET MODE
(Orange)
Lights up in Jet Mode
Operation.
Operation.
Operation Mode Selection
Fan Speed Selection
Jet Mode Operation OFF/ON
•
Jet Mode operation for fast cooling
FAN
SPEED
JET
MODE
•
High Fan Speed or Low Fan Speed
MODE
•
Cooling Operation Mode or Fan Operation
Mode
TIIMER
•
To set delay OFF Timer.
Timer Operation Setting
Room Temperature and Timer Setting
TEMP/
TIMER
TIMER
•
Cooling Operation Mode
- Temperature Setting ( 16
o
C ~ 30
o
C )
•
Timer Setting
- Timer Setting ( 1 ~ 12 hours )
SET/
CANCEL
•
To start delay OFF or cancelation
Delay OFF Timer OFF/ON
Random Auto Restart Control
•
Random auto restart after power failure at
previous setting mode
.
Freeze Prevention Control
•
Freeze prevention control for the Evapora-
tor. (Cooling Operation Only)
Starting Current Control
•
Fan Motor is delayed for 1.6 seconds
when Compressors starts simultaneously.
Time Delay safety Control
•
Restarting is inhibited for approximately 3
minutes.
60 Secs. Forced Operation Control
•
Once the compressor is activated, it does
not stop within the first 60 seconds.
However, it stops immediately with
remote control stop signal.
However, it stops immediately with
remote control stop signal.
Compressor Reverse Rotation Protection
Control.
Control.
•
To protect compressor from reverse
rotation when there is an instantaneous
power failure.
power failure.
Over Load Protector
•
Overload protector will trip to protect the
compressor when it is overheated.
Panasonic
- 3-