CU-4E27PBD, CU-5E34PBD - Panasonic Air Conditioner Service Manual (repair manual). Page 52

Read Panasonic CU-4E27PBD / CU-5E34PBD Service Manual online

52 
š Heating 
Characteristic 
[Condition] Room 
temperature: 20°C (DBT), 12°C (WBT) 
 
Operation condition: High fan speed 
 
Piping Length: 5m 
 
230V  50Hz 
 
A) Indoor unit capacity: Heating (2.2: CS-E7PKDW) 
 
 
 
 
 
 
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
Ou
td
o
o
r
T
e
mper
at
ure
 (
°C
)
Outdoor Air Temperature (°C)
230
1.000
1.500
2.000
2.500
3.000
3.500
4.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
H
eating
C
apacity
 (kW
)
Outdoor Air Temperature (°C)
4.300
4.400
4.500
4.600
4.700
4.800
4.900
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
C
u
rrent
(A
)
Outdoor Air Temperature (°C)
1.000
1.200
1.400
1.600
1.800
2.000
2.200
2.400
2.600
2.800
3.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
G
a
s S
ide 
P
iping
P
ressure (MP
a
)
Outdoor Air Temperature (°C)
Page of 60