Read Panasonic CU-4E27PBD / CU-5E34PBD Service Manual online
52
Heating
Characteristic
[Condition] Room
temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping Length: 5m
230V 50Hz
A) Indoor unit capacity: Heating (2.2: CS-E7PKDW)
28.000
30.000
32.000
34.000
36.000
38.000
40.000
42.000
44.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
Ou
td
o
o
r
T
e
mper
at
ure
(
°C
)
Outdoor Air Temperature (°C)
230
1.000
1.500
2.000
2.500
3.000
3.500
4.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
H
eating
C
apacity
(kW
)
Outdoor Air Temperature (°C)
4.300
4.400
4.500
4.600
4.700
4.800
4.900
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
C
u
rrent
(A
)
Outdoor Air Temperature (°C)
1.000
1.200
1.400
1.600
1.800
2.000
2.200
2.400
2.600
2.800
3.000
-15
-13
-11
-9
-7
-5
-3
-1
1
3
5
7
9
11
13
G
a
s S
ide
P
iping
P
ressure (MP
a
)
Outdoor Air Temperature (°C)
Click on the first or last page to see other CU-4E27PBD / CU-5E34PBD service manuals if exist.