12
Model
Indoor CS-Z25UD3EAW
CS-Z35UD3EAW
Outdoor CU-Z25UBEA
CU-Z35UBEA
Weight
Net (I/D / O/D)
kg (lb)
19 (42) / 33 (73)
19 (42) / 35 (77)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 20 (65.6)
3 (9.8) ~ 20 (65.6)
I/D & O/D Height different
m (ft)
15.0 (49.2)
15.0 (49.2)
Additional Gas Amount
g/m (oz/ft)
10 (0.1)
10 (0.1)
Length for Additional Gas
m (ft)
7.5 (24.6)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
16
16
Length mm
117.5
117.5
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Pre Coat)
Fin Type
Slit Fin
Slit Fin
Row × Stage × FPI
3 × 12 × 18
3 × 12 × 18
Size (W × H × L)
mm
590 × 282 × 38.1
590 × 282 × 38.1
Outdoor
Heat
Exchanger
Fin Material
Aluminium
Aluminium
Fin Type
Corrugated Fin
Corrugated Fin
Row × Stage × FPI
2 × 24 × 19
2 × 28 × 17
Size (W × H × L)
mm
36.4 × 504 × 824.2:793.7
36.38 × 588 × 856.3:827.7
Air Filter
Material
–
–
Type
–
–
Power Supply
Outdoor
Outdoor
Power Supply Cord
A
Nil
Nil
Thermostat
Electronic Contol
Electronic Contol
Protection Device
Electronic Contol
Electronic Contol
Dry Bulb
Wet Bulb
Dry Bulb
Wet Bulb
Indoor
Operation
Range
Cooling
Maximum
°C
32 23 32 23
Minimum
°C
16 11 16 11
Heating
Maximum
°C
30 – 30 –
Minimum
°C
16 – 16 –
Outdoor
Operation
Range
Cooling
Maximum
°C
43 26 43 26
Minimum
°C
-10 – -10 –
Heating
Maximum
°C
24 18 24 18
Minimum
°C
-15 -16 -15 -16
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control).
6.
Specifications are subjected to change without prior notice for further improvement.
Click on the first or last page to see other CS-Z25UD3EAW / CS-Z35UD3EAW / CS-Z50UD3EAW / CS-Z60UD3EAW / CU-Z25UBEA / CU-Z35UBEA / CU-Z50UBEA / CU-Z60UBEA service manuals if exist.