1.  Release fixing 
screws on both side, disassembly the fixing board from 
evaporator on the 
left side and pull out the whole evaporator. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2. Loose the fixing screw of the cross flow fan.    
     
3.  After removing the bearing, indoor fan can be taken out from the left side 
 
4. Lift up the indoor fan slightly, and then pull the fan motor out. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Removal Procedure for Cross Flow Fan 
Fixing Screw 
Bearing 
Fan motor 