17.3. Sensible Capacity Chart
Condition
Indoor temperature : 27
qC / 19qC
Outdoor temperature : 35
qC / 24qC
CS-XE9EKE CU-XE9EKE
CS-XE12EKE CU-XE12EKE
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)
230V - 240V
Outdoor Temperature (
qC)
Indoor wet bulb
temperature
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
2.58
1.96
0.52
2.41
1.88
0.56
2.24
1.80
0.60
2.04
1.71
0.65
19.0
qC
2.60
0.57
19.5
qC
2.83
2.05
0.53
2.65
1.97
0.57
2.46
1.89
0.61
2.24
1.80
0.66
22.0
qC
3.09
2.12
0.54
2.88
2.04
0.58
2.68
1.97
0.62
2.44
1.88
0.67
230V - 240V
Outdoor Temperature (
qC)
Indoor wet bulb
temperature
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
3.47
2.63
0.81
3.24
2.52
0.87
3.02
2.43
0.93
2.74
2.30
1.00
19.0
qC
3.50
0.88
19.5
qC
3.81
2.76
0.82
3.56
2.65
0.88
3.31
2.55
0.95
3.01
2.43
1.02
22.0
qC
4.15
2.86
0.84
3.88
2.75
0.90
3.61
2.65
0.96
3.28
2.53
1.04