3.2. CS-XE12DKE CU-XE12DKE
Unit
CS-XE12DKE
CU-XE12DKE
Cooling Capacity
kW
kcal/h
BTU/h
3.45 (0.60 - 4.00)
2,970 (520 - 3,440)
11,800 (2,050 - 13,600)
Heating Capacity
kW
kcal/h
BTU/h
4.80 (0.60 - 6.50)
4,130 (520 - 5,590)
16,400 (2,050 - 22,200)
Moisture Removal
l/h
Pint/h
2.0
(4.2)
Power Source (Phase, Voltage, Cycle)
ø
V
Hz
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Lo
m
3
/min (cfm)
Cooling; 7.3 (258)
Heating; 9.2 (325)
Me
m
3
/min (cfm)
Cooling; 9.2 (323)
Heating; 10.3 (360)
Hi
m
3
/min (cfm)
Cooling; 10.9 (380)
Cooling; 31.0 (1,090)
Heating; 11.8 (420)
dB (A)
Cooling; High 42, Low 29
Cooling; 48
Heating; High 42, Low 33
Heating; 50
Noise Level
Power level dB
Cooling; High 53
Cooling; High 61
Heating; High 53
Heating; High 63
Electrical Data
Input
W
Cooling; 950 (120 - 1,280)
Heating; 1,260 (115 - 1,890)
Running Current
A
Cooling; 4.4
Heating; 5.6
EER
W/W (kcal/hw), BTU/hw
Cooling; 3.63 (3.13), 12.4
COP
W/W (kcal/hw), BTU/hw
Heating; 3.81 (3.28), 13.0
Starting Current
A
5.60
Piping Connection Port
(Flare piping)
inch
inch
G ; Half Union 1/2”
L ; Half Union 1/4”
G ; 3-way valve 1/2”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
inch
inch
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
G (gas side) ; 1/2”
L (liquid side) ; 1/4”
8