Read Panasonic CS-XE9DKE / CU-XE9DKE / CS-XE12DKE / CU-XE12DKE Service Manual online
2.2. INDOOR UNIT
Operation Indication Lamps (LED)
• POWER (Green) .....
Lights up in operation,
blinks in Automatic
Operation Mode judging
deice, ON Timer sampling
and Hot Start operation.
blinks in Automatic
Operation Mode judging
deice, ON Timer sampling
and Hot Start operation.
•
(Green) .......
Lights up in Oxygen Mode
Operation.
Operation.
• ION (Green) ...........
Lights up in Ionizer Mode
Operation. Blinks in Ionizer
error.
Operation. Blinks in Ionizer
error.
• QUIET (Orange) .....
Lights up in Quiet Mode
Operation.
Operation.
• TIMER (Orange) .....
Lights up in Timer Setting.
Blinks in Self Diagnosis
Control.
Blinks in Self Diagnosis
Control.
Five Operation Modes
• Heating, Cooling, Soft Dry, Fan and Automatic
Mode.
Oxygen Operation
• To suppy oxygen enrich air.
Quiet Operation
• To provide quiet operation.
Ionizer Control
• Ionizer control for generate negative ion in
discharge air.
Automatic and 5 Manual Indoor Fan
Speeds
Speeds
Automatic and 5 Manual Vertical
Airflow Directions
Airflow Directions
Automatic and 5 Manual Horizontal
Airflow Directions
Airflow Directions
• Press for < 5s to operate Automatic operation
mode.
(Used when the remote control cannot be
used.)
(Used when the remote control cannot be
used.)
• Press continuously for 5s or < 8s to operate
Test Run/Pump down. “Beep” sound will be
heard.
(Used when test running or servicing.)
heard.
(Used when test running or servicing.)
• Press continuously for 8s or < 11s to operate
Forced Heating Operation. “Beep, beep”
sound will be heard.
sound will be heard.
• Press continuously for 11s or < 16s to change
different remote control setting (A
↔B Mode),
or testify oxygen operation “Beep, beep, beep”
sound will be heard.
sound will be heard.
• Press continuously for 16s or < 21s to omit or
resume the remote control signal receiving
sound or H14 Abnormality Detection Mode.
sound or H14 Abnormality Detection Mode.
Automatic Operation Switch
Random Auto Restart Control
• Operation is restarted randomly after power
failure at previous setting mode.
Delay ON Timer and OFF Timer
Microcomputer-controlled Room
Temperature Control
Temperature Control
Hot Start
Low Pressure Control
(Gas Leakeage Detection)
(Gas Leakeage Detection)
Indoor Power Relay Control
Deodorizing Control
Anti-Dew Formation Control
Anti Freezing Control
Anti-Cold Draft Control
Intake Air Temperature Control
High Pressure Control
Deice Operation
Breakdown Self Diagnosis Function
AUTO
OFF / ON
4
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
Click on the first or last page to see other CS-XE9DKE / CU-XE9DKE / CS-XE12DKE / CU-XE12DKE service manuals if exist.