REMARKS
B
: BLUE
P
: PINK
BR
: BROWN
R
: RED
BL
: BLACK
W
: WHITE
G
: GREEN
Y
: YELLOW
GRY
: GRAY
Y/G
: YELLOW/GREEN
O
: ORANGE
Resistance of Indoor Fan Motor Windings
MODEL
CS-XC9CK
CS-XC12CK
CONNECTION
CWA921181
BLUE-YELLOW
390
YELLOW-RED
390
Note: Resistance at 20°C/25°C of ambient temperature.
Resistance of Outdoor Fan Motor Windings
MODEL
CU-XC9CK
CONNECTION
CWA951114
BLUE-YELLOW
259
YELLOW-RED
235
MODEL
CU-XC12CK
CONNECTION
CWA951116
BLUE-YELLOW
230
YELLOW-RED
255
Note: Resistance at 20°C of ambient temperature.
Resistance of Compressor Windings
MODEL
CU-XC9CK
CU-XC12CK
CONNECTION
2PS146D3AA04
2KS206D5AF04
C-R
3.941
2.234
C-S
3.499
2.630
Note: Resistance at 20°C/25°C of ambient temperature.