Read Panasonic CS-TZ50TKEW / CU-TZ50TKE Service Manual online
120
21. Service
Data
Service data provided are based on the air conditioner running under rated frequency during forced cooling / forced
heating mode.
heating mode.
21.1 Cool Mode Outdoor Air Temperature Characteristic
Condition
-
Indoor room temperature: 27°C Dry Bulb/19°C Wet Bulb
-
Unit setting: Standard piping length, forced cooling at 16°C, Hi fan
-
Compressor frequency: Rated for cooling operation
-
Piping length: 5m
- Voltage:
230V
Indoor Discharge
Air Temperature (°C)
Outdoor Air Temperature (°C)
Low Pressure (MPa)
Outdoor Air Temperature (°C)
Current (A)
Outdoor Air Temperature (°C)
3.00
4.00
5.00
6.00
7.00
8.00
14.0
15.0
16.0
17.0
18.0
9
11 13 15 17 13 21 23 25 27 29 31 33 35 37 39 41 43 45
9
11 13 15 17 13 21 23 25 27 29 31 33
35 37 39
41 43 45
9
11 13 15 17 13 21 23 25
27 29 31 33 35 37 39
41 43 45
0.90
1.00
1.10
Click on the first or last page to see other CS-TZ50TKEW / CU-TZ50TKE service manuals if exist.