Technical data provided are based on the air conditioner running under free frequency. 
 
20.1  Cool Mode Performance Data 
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C 
Voltage: 230V 
 
Indoor (°C) 
Outdoor DB (°C) 
DB WB 
-10 -7  0  5  16 25 35 
TC SHC IP  TC SHC IP  TC SHC
IP  TC SHC
IP TC 
SHC
IP TC 
SHC IP TC 
SHC
IP 
27 
19  5291 4210 1078 5317 4237 1072 5338 4175 1078 5186 4200 1255 5838 4534 857  5442 4432 1137 5000 4089 1470
22  5837 3388 1091 5744 3384 1186 5772 3377 1153 6003 3462 999 6430 3682 821  5963 3480 1124 5317 3262 1476
23 
15.7  4727 4679 1154 4762 4151 1103 4714 4112 1207 4743 4696 1177 5260 5207 885  4878 4247 1148 4315 4068 1470
18.4  5226 3360 1079 5263 3354 1043 5299 3376 1079 5099 3317 1229 5590 3512 864  5322 3465 1139 4784 3250 1472
20 
13.3  4198 4156 1320 4160 3848 1103 4490 4085 1155 4357 3943 1205 4948 4899 905  4493 4142 1152 4009 3880 1467
15.8  4768 3315 1152 4756 3308 1092 4728 3267 1212 4637 3221 1266 5203 3491 884  4847 3358 1146 4348 3157 1471
 
(Dry bulb value based on 46% humidity) 
 
TC     - Total Cooling Capacity (W) 
SHC  - Sensible Heat Capacity (W) 
IP      - Input Power (W) 
 
20.2  Heat Mode Performance Data 
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C 
Voltage: 230V 
 
Indoor (°C) 
Outdoor WB (°C) 
DB 
-15 -7  2  7  12 
TC IP TC IP TC IP TC IP TC IP 
24  3905 1887 4185 1962 5488 1992 5254 1542 5593 1534 
20  3911 1785 4790 1950 5650 2040 5800 1540 5818 1534 
16  3686 1690 4742 1867 5686 1941 6006 1538 6166 1531 
 
TC     - Total Cooling Capacity (W) 
SHC  - Sensible Heat Capacity (W) 
IP      - Input Power (W) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 