CS-SA7CKP, CU-SA7CKP5, CS-SC7CKP, CU-SC7CKP5 - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-SA7CKP / CU-SA7CKP5 / CS-SC7CKP / CU-SC7CKP5 Service Manual online

* The amount of refrigerant (60g) for air purging not included.
Unit
CS-SC7CKP
CU-SC7CKP5
Air Circulation
Type
Cross-flow Fan
Propeller fan
Motor
Type
Induction (4 pole)
Induction (4 pole)
Input
W
31
60.7
Rate Output
W
13
15
Fan Speed
Low
rpm
920±60
Medium
rpm
1040±60
High
rpm
1170±60
875±30
Heat Exchanger
Description
Evaporator
Condenser
Tube Material
copper
copper
Fin Type
slot type
Corrugation type
Rows / Stage
(Plate fin configuration, forced draft)
2 × 10
1 × 20
FPI
18
16
Dimensions
mm
610 × 210 × 25.4
578.25 × 508 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
SUNISO 4GDID or ATMOS M60
(M56)
Refrigerant (R-22)
g
530*
Thermostat
Electronic Control
Protection Device
OLP(30A/230V)
Capillary
Length
mm
865
Circulation
L/min
6.8
Inner Diameter
mm
1.3
Air Filter
P.P Honeycomb
Refrigerant Circulation Control Device
Capillary
Compressor Capacitor
µFV
30µF, 400V
Fan Motor Capacitor
µFV
1.5µF, 400V
1.2µF, 400V
     • 
• 
• 
• Specifications are subject to change without notice for further improvement.