8
Height(I/D / O/D)
mm (inch)
290 (11-15/32)
540 (21-1/4)
Width (I/D / O/D)
mm (inch)
848 (33-13/32)
780 (30-23/32)
Dimension
Depth (I/D / O/D)
mm (inch)
204 (8-1/32)
289 (11-3/8)
Weight
Net (I/D / O/D)
kg (lb)
9.0 (20)
30 (66)
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.7 (1/2)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 10 (32.8)
I/D & O/D Height different
m (ft)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.3)
Piping
Length for Additional Gas
m (ft)
7.0 (23.0)
Inner Diameter
mm
16
Drain Hose
Length mm
500
Fin Material
Pre coated
Fin Type
Slit fin
Row x Stage x FPI
2 x 15 x 18
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
Fin Material
Bear Fin
Fin Type
Slit fin
Row x Stage x FPI
1 x 24 x 18
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
12.7 x 504.0 x 719.2
Material
P.P,HONEY
COMB
Air Filter
Type
One-touch
Power Supply
Indoor
Power Supply Cord
A
10
Thermostat
-
Protection Device
-
DRY BULB
WET BULB
Maximum 32
23
Indoor Operation Range
Minimum 16
11
Maximum 43
26
Outdoor Operation Range
Minimum 16
11
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)