CS-PC7KKD, CS-PC9KKD, CS-PC12KKD, CU-PC7KKD, CU-PC9KKD, CU-PC12KKD - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-PC7KKD / CS-PC9KKD / CS-PC12KKD / CU-PC7KKD / CU-PC9KKD / CU-PC12KKD Service Manual online

Pipe Diameter (Liquid / 
Gas) 
mm (inch)
6.35 (1/4) / 9.52 (3/8) 
6.35 (1/4) / 9.52 (3/8) 
Standard length 
m (ft) 
5.0 (16.4) 
5.0 (16.4) 
Length range (min – max) 
m (ft) 
3 (9.8) ~ 7 (23.0) 
3 (9.8) ~ 7 (23.0) 
I/D & O/D Height different 
m (ft) 
5.0 (16.4) 
5.0 (16.4) 
Additional Gas Amount 
g/m (oz/ft)
Piping 
Length for Additional Gas 
m (ft) 
Inner Diameter 
mm  
16 
16 
Drain Hose 
Length mm 
500 
500 
Fin Material 
 
Pre coated 
Pre coated 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x 
FPI 
 
2 x 15 x 18 
2 x 15 x 18 
Indoor Heat 
Exchanger 
Size (W x H x L) 
mm 
610 x 315 x 25.4 
610 x 315 x 25.4 
Fin Material 
 
Bear Fin 
Bear Fin 
Fin Type 
 
Slit Fin 
Slit Fin 
Row x Stage x 
FPI 
 
1 x 24 x 18 
1 x 24 x 18 
Outdoor 
Heat 
Exchanger 
Size (W x H x L) 
mm 
12.7 x 504.0 x 570.7             
12.7 x 504.0 x 570.7 
Material 
 
P.P.HONEY COMB 
P.P.HONEY COMB 
Air Filter 
Type  
One-touch 
One-touch 
Power Supply 
 
Indoor 
Indoor 
Power Supply Cord 
10 
10 
Thermostat  
Protection Device 
 
 
DRY BULB 
WET BULB 
DRY BULB 
WET BULB 
Maximum
32 23 
32 
23 
Indoor Operation Range 
Minimum
16 11 
16 
11 
Maximum
43 26 
43 
26 
Outdoor Operation Range 
Minimum
16 11 
16 
11 
1. 
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and 
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB) 
 
Page of 35