11.7  Dew Prevention Control 
To prevent dew formation at indoor unit discharge area, the horizontal air vane is automatically set at position 2 
(refer to 10.7). 
This control is activated when:- 
*Compressor runs continuously for 60 minutes. 
*Horizontal air vane is at position 4 or 5 (refer to 10.7). 
*Actual fan speed is lower than Lo level. 
*Intake air temperature is lower than 29℃ 
*Intake air temperature changes within 2℃ for more than 30 minutes. 
Dew prevention stops when:- 
Any of the above condition is out of the range described above. 
Operation stops. 
Power OFF. 
 
11.8  Compressor Overload Protection Control 
During heating mode, when temperature of indoor heat exchanger rises to 51℃, outdoor fan will stop. 
When temperature of indoor heat exchanger falls to 49℃ 
 
When temperature of indoor heat exchanger rises to 65℃ or above, compressor stops, and will restart 4 minutes 
later. 
 
 
11.9  4-Way Valve Control 
z  4-way valve always on during heating operation except deicing operation. 
z  When the unit is switched off by remote control during Heating operation, the 4-way valve stay at Heating 
position for 5 minutes (Maximum). 
 
11.10  Warm Booting Control 
z  When turning on the unit by heating mode operation, indoor fan will be activated when temperature of indoor 
heat exchanger reaches 30℃.  
z  Warm boot operation ends when temperature of indoor heat exchanger reaches 34℃. 
 
 
 
 