CS-PA7CKE, CU-PA7CKE, CS-PC7CKE, CU-PC7CKE, CS-PA9CKE, CU-PA9CKE, CS-PC9CKE, CU-PC9CKE, CS-PA12CKE, CU-PA12CKE, CS-PC12CKE, CU-PC12CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 10

Read Panasonic CS-PA7CKE / CU-PA7CKE / CS-PC7CKE / CU-PC7CKE / CS-PA9CKE / CU-PA9CKE / CS-PC9CKE / CU-PC9CKE / CS-PA12CKE / CU-PA12CKE / CS-PC12CKE / CU-PC12CKE Service Manual online

S%('
</H,P"+<QR
<SH,P"+<QR
Air Circulation
Type
Cross-flow Fan
Propeller fan
Motor
Type
Induction (4 pole)
Induction (4 pole)
Input
W
38.4
54.8
Rated Output
W
13
20
Fan Speed
Low
rpm
980±60
Medium
rpm
1090±60
High
rpm
1200/1270±60
760±60
Heat Exchanger
Description
Evaporator
Condenser
Tube Material
copper
copper
Fin Type
slot type
Corrugation type
Rows / Stage
(Plate fin configuration, forced draft)
2 × 15
1 × 20
FPI
18
18
Dimensions
mm
610 × 315 × 25.4
838.9 × 508 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
SUNISO 4GDID or ATMOS M60
(M56)
Refrigerant (R-22)
g
1000
Thermostat
Electronic Control
Protection Device
OLP(30A/230V)
Capillary
Length
mm
Cooling: 690 Heating: 665
Circulation
L/min
Cooling: 60 Heating: 16.1
Inner Diameter
mm
Cooling: 1.2 Heating: 1.7
Air Filter
P.P Honeycomb
Refrigerant Circulation Control Device
Capillary
Compressor Capacitor
µFV
30µF, 370V
Fan Motor Capacitor
µFV
1.5µF, 400V
1.8µF, 440V
 • Specifications are subject to change without notice for further improvement.
10
</H,P8<QR Y <SH,P8<QR Y </H,<8<QR Y <SH,<8<QR
Page of 85
Display

Click on the first or last page to see other CS-PA7CKE / CU-PA7CKE / CS-PC7CKE / CU-PC7CKE / CS-PA9CKE / CU-PA9CKE / CS-PC9CKE / CU-PC9CKE / CS-PA12CKE / CU-PA12CKE / CS-PC12CKE / CU-PC12CKE service manuals if exist.