CS-PA7CKE, CU-PA7CKE, CS-PC7CKE, CU-PC7CKE, CS-PA9CKE, CU-PA9CKE, CS-PC9CKE, CU-PC9CKE, CS-PA12CKE, CU-PA12CKE, CS-PC12CKE, CU-PC12CKE - Panasonic Air Conditioner Service Manual (repair manual). Page 8

Read Panasonic CS-PA7CKE / CU-PA7CKE / CS-PC7CKE / CU-PC7CKE / CS-PA9CKE / CU-PA9CKE / CS-PC9CKE / CU-PC9CKE / CS-PA12CKE / CU-PA12CKE / CS-PC12CKE / CU-PC12CKE Service Manual online

S%('
</H,PG<QR
<SH,PG<QR
Air Circulation
Type
Cross-flow Fan
Propeller fan
Motor
Type
Induction (4 pole)
Induction (4 pole)
Input
W
38.4
55.3
Rated Output
W
13
20
Fan Speed
Low
rpm
900±60
Medium
rpm
1040±60
High
rpm
1180/1200±60
740±60
Heat Exchanger
Description
Evaporator
Condenser
Tube Material
copper
copper
Fin Type
slot type
Corrugation type
Rows / Stage
(Plate fin configuration, forced draft)
2 × 15
1 × 19
FPI
18
18
Dimensions
mm
610 × 315 × 25.4
706.2 × 482.6 × 22
Refrigerant Control Device
Capillary Tube
Refrigeration Oil
(c.c)
SUNISO 4GDID or ATMOS M60
(M56)
Refrigerant (R-22)
g
840
Thermostat
Electronic Control
Protection Device
OLP(30A/230V)
Capillary
Length
mm
Cooling: 470 Heating: 1160
Circulation
L/min
Cooling: 13.4 Heating: 4.5
Inner Diameter
mm
Cooling: 1.5 Heating: 1.2
Air Filter
P.P Honeycomb
Refrigerant Circulation Control Device
Capillary
Compressor Capacitor
µFV
25µF, 370V
Fan Motor Capacitor
µFV
1.5µF, 400V
1.2µF, 400V